Kern F2 OIML Calibration Weights

Our Price: £10.00£765.00 + VAT (£12.00 - £918.00 inc VAT)

Kern Stainless Steel F2 OIML Standard Test Weights / Calibration Weights

For UKAS 1 certificate is required per weight ordered.

Description

Kern Stainless Steel F2 OIML Calibration Weights

High quality stainless steel F2 OIML Calibration Weights for testing laboratory balances and scales.

Testing Guideline:

These F2 OIML Calibration Weights can be used to test the scales and balances prior to use to ensure the performance of the equipment is correct prior to weighing products.

These weights can can also be used to calibrate the scales and balances if they are out of spec or in need of adjustment.

It is recommended to purchase these weights with either a UKAS ISO17025 or DAkks (German UKAS) certificate to ensure accuracy and for audit purposes.

DAkks is recognised by UKAS and conforms to ISO17025

Used in many industries and laboratories, such as Pharmaceutical, Chemical, Flavours, Fragrances, Food Production and many more.

See our downloads for some useful tips on test weights and also guides on how to handle them.

Test Weight Material:

• Milligram weights: Stainless Steel, flat polygonal sheet
• Calibration weights of 1g or above are Stainless Steel, knob shape

All weights come with a plastic carry casing.

MPN:

338-01 – 1mg F2

338-02 – 2mg F2

338-03 – 5mg F2

338-04 – 10mg F2

338-05 – 20mg F2

338-06 – 50mg F2

338-07 – 100mg F2

338-08 – 200mg F2

338-09 – 500mg F2

337-01 – 1g F2

337-02 – 2g F2

337-03 – 5g F2

337-04 – 10g F2

337-05 – 20g F2

337-06 – 50g F2

337-07 – 100g F2

337-08 -200g F2

337-09 – 500g F2

337-11 – 1kg F2

337-12 – 2kg F2

337-13 – 5kg F2

337-14 – 10Kg F2

337-15 – 20kg F2

 

Downloads

PDF-Download

PDF-Download

PDF-Download

We endeavour to deliver your goods to you as fast as we can. A large percentage of our orders are delivered in 3 - 5 working days (all mainland UK postcodes except IV, AB and KW) but some goods can take longer if they are delivered direct from the manufacturer or if the item is made to order. Please note, IV, AB and KW postcodes and non-mainland UK including Northern Ireland can take longer. Please give us a call if your order is urgent to verify the delivery time or see if a faster delivery is possible (additional costs may apply for larger orders).

The following delivery charges may apply per order:
  • £12.00 + VAT – Mainland UK
  • £30.00 + VAT – UK non-mainland

Reviews

There are no reviews yet.

Be the first to review “Kern F2 OIML Calibration Weights”

Your email address will not be published. Required fields are marked *

Frequently Asked Questions

Please see below for answers to frequently asked questions.

A calibration certificate proves the accuracy of your weighing equipment. It is very likely that if accuracy matters in your workplace, certification will be required by your industry regulators. They are straightforward to get hold of though. Just ask our team.

If you are trading or transacting anything by weight, you will probably need to demonstrate your weighing equipment is verified for trade use. This gives your customers confidence in your business and will make sure buying and selling run smoothly. We can help get you with relevant approvals for your equipment.

The answer will vary depending on how your equipment is used. As a minimum, we typically recommend once a year but our team can provide advice based on your individual circumstances.

The International Organization of Legal Metrology (OIML) has established standards for the classification of calibration test weights. Varying from E0 & E1, which are the most accurate to M2 which are commonly used for calibrating platform scales, floor scales and other industrial weighing instruments.

As a rough guide we have listed desired accuracy against class below.

+/- 0.1% – UNclassed Proof Load Test Weights
+/- 0.05% – M3 (Check/calibrate coarse scales)
+/- 0.005% – M1 (Check/calibrate standard scales)
+/- 0.0015% – F2 (Check/calibrate portable balances)
+/- 0.0005% – F1 (Check/calibrate precision balances)
+/- 0.00015% – E2 (Check/calibrate analytical balances)

The choice of weight class depends on the intended use and the level of accuracy required for a particular application. If you’re unsure, talk to our team who can advise you on the right class for your equipment.

If you’re sending a scale back to us for recalibration, it is ideal to use the original packaging. If this is not available choose a sturdy well-padded box to avoid shocks. Where possible, protect the load sensor by removing the weighing pan and any under-pan support and pack these separately in the box. You may be able to use the equipment’s locking pins or screws too.

Do ensure all the paperwork, including your contact details, is included to ensure we can return it once calibration is complete.

Need help? Speak to one of our experts Contact Us